Click on Image For  large Picture size...


DETAILS UITS HAG 10 HAG 20 HAG 30 HAG 40 HAG 60
Rated hit output kcal/hr 100000 200000 300000 400000 600000
Maximum Air Temp. 200 200 200 200 200
Outlet Air Pressure mm of Water G. 100 100 100 100 100
Approx Hot Air Available at 200°C kg/hr. 2290 4580 6870 9160 13740
m³/hr 1910 3815 5725 7585 11450
Overall Thermal Efficiency On GCV % 86± 1
Fuel Oil Consumption for rated out put LDO (GCV 10200)kcal/kg kg / hr 10.70 21.5 32.2 45.6 64.3
F.O. (GCV 10200 kcal/kg kg/hr - 23.8 39.8 48 67.6


   BURNER CONTROL                       <-------------------  ON-OFF  ------------------->      HIGH/LOW
  
Electric Supply                                                   415V±5% 50 Hz 3ph 4 Wire

Main Air Blower motor kw 3.75 5.0 7.5 0.27 11.25
Combustion Air Blower motor kw 0.75 0.75 1.5 2.25 3.75
Fuel oil preheeteer (for operation o FO) - - 3.0 6.0 6.0
 Overall
Dimension
 (Approx)
  Height mm 1500 2000 2200 2500 2800
  Length mm 2500 3000 3500 4800 4000
  Width mm 1100 1500 1500 1800 2500
Dry Weight   Approx kgs 1200 2000 2800 3500 5300



Click on Image For  large Picture size...

 

 

Copyright©2006, All Right Reserved, Thermtech Industries